Chart
Solar Pile Weight Chart & Calculator
Weight per foot and per pile for the 16 W6 and W8 wide flange sections driven as solar piles, bare and hot-dip galvanized, with the ASTM A123 coating grade of each section. Figure a pile schedule’s weight, or estimate the pile count from your tracker layout.
Solar pile sections: dimensions and weight
The 16 AISC wide flange sections from W6×8.5 to W8×35, with the nominal weight, the dimensions, the surface to galvanize per foot and the ASTM A123 coating grade for the web and the flanges. Each size links to its row in the full W-Beam size table.
| Section | lb/ft | kg/m | Depth (in.) | Flange width (in.) | Web (in.) | Flange (in.) | Surface (ft²/ft) | A123 grade |
|---|---|---|---|---|---|---|---|---|
| W6×8.5 | 8.5 | 12.6 | 5.830 | 3.940 | 0.170 | 0.195 | 2.26 | 75 |
| W6×9 | 9 | 13.4 | 5.900 | 3.940 | 0.170 | 0.215 | 2.27 | 75 |
| W6×12 | 12 | 17.9 | 6.030 | 4.000 | 0.230 | 0.280 | 2.30 | 75 / 100 |
| W6×15 | 15 | 22.3 | 5.990 | 5.990 | 0.230 | 0.260 | 2.96 | 75 / 100 |
| W6×16 | 16 | 23.8 | 6.280 | 4.030 | 0.260 | 0.405 | 2.35 | 100 |
| W6×20 | 20 | 29.8 | 6.200 | 6.020 | 0.260 | 0.365 | 3.00 | 100 |
| W6×25 | 25 | 37.2 | 6.380 | 6.080 | 0.320 | 0.455 | 3.04 | 100 |
| W8×10 | 10 | 14.9 | 7.890 | 3.940 | 0.170 | 0.205 | 2.60 | 75 |
| W8×13 | 13 | 19.3 | 7.990 | 4.000 | 0.230 | 0.255 | 2.63 | 75 / 100 |
| W8×15 | 15 | 22.3 | 8.110 | 4.020 | 0.245 | 0.315 | 2.65 | 75 / 100 |
| W8×18 | 18 | 26.8 | 8.140 | 5.250 | 0.230 | 0.330 | 3.07 | 75 / 100 |
| W8×21 | 21 | 31.3 | 8.280 | 5.270 | 0.250 | 0.400 | 3.10 | 100 |
| W8×24 | 24 | 35.7 | 7.930 | 6.500 | 0.245 | 0.400 | 3.45 | 75 / 100 |
| W8×28 | 28 | 41.7 | 8.060 | 6.540 | 0.285 | 0.465 | 3.48 | 100 |
| W8×31 | 31 | 46.1 | 8.000 | 8.000 | 0.285 | 0.435 | 3.95 | 100 |
| W8×35 | 35 | 52.1 | 8.120 | 8.020 | 0.310 | 0.495 | 3.97 | 100 |
Nominal weights and dimensions from the AISC Shapes Database v16.0. Surface = (2 × depth + 4 × flange width − 2 × web) ÷ 12, the outline of the section with the fillets ignored. A123 grade from ASTM A123 Table 1 for structural shapes: 75 for steel 1/8 in. to under ¼ in. thick, 100 for ¼ in. and thicker; where web and flanges differ it reads web / flange.
Weight per pile by length
Bare steel weight of one pile at common lengths. Piles are cut to the lengths in the racking pier table, so a project usually has several lengths of the same section.
| Section | 8 ft | 10 ft | 12 ft | 14 ft | 16 ft | 18 ft | 20 ft |
|---|---|---|---|---|---|---|---|
| W6×8.5 | 68 | 85 | 102 | 119 | 136 | 153 | 170 |
| W6×9 | 72 | 90 | 108 | 126 | 144 | 162 | 180 |
| W6×12 | 96 | 120 | 144 | 168 | 192 | 216 | 240 |
| W6×15 | 120 | 150 | 180 | 210 | 240 | 270 | 300 |
| W6×16 | 128 | 160 | 192 | 224 | 256 | 288 | 320 |
| W6×20 | 160 | 200 | 240 | 280 | 320 | 360 | 400 |
| W6×25 | 200 | 250 | 300 | 350 | 400 | 450 | 500 |
| W8×10 | 80 | 100 | 120 | 140 | 160 | 180 | 200 |
| W8×13 | 104 | 130 | 156 | 182 | 208 | 234 | 260 |
| W8×15 | 120 | 150 | 180 | 210 | 240 | 270 | 300 |
| W8×18 | 144 | 180 | 216 | 252 | 288 | 324 | 360 |
| W8×21 | 168 | 210 | 252 | 294 | 336 | 378 | 420 |
| W8×24 | 192 | 240 | 288 | 336 | 384 | 432 | 480 |
| W8×28 | 224 | 280 | 336 | 392 | 448 | 504 | 560 |
| W8×31 | 248 | 310 | 372 | 434 | 496 | 558 | 620 |
| W8×35 | 280 | 350 | 420 | 490 | 560 | 630 | 700 |
Pounds of bare steel: lb/ft × length. Add the zinc from Table 3 for a galvanized pile.
Galvanized solar pile weight
Hot-dip galvanizing adds the weight of the zinc: the coated surface per foot times the coating mass. ASTM A123 Table 2 gives the mass of each grade, 530 g/m² for grade 75 (3.0 mil) and 705 g/m² for grade 100 (3.9 mil); a 6.0 mil coating is about 1,074 g/m². At the A123 minimum, the web and the flanges each carry the grade for their own thickness.
| Section | Bare (lb/ft) | A123 minimum (lb/ft) | 3.9 mil (lb/ft) | 6.0 mil (lb/ft) | Zinc at A123 minimum |
|---|---|---|---|---|---|
| W6×8.5 | 8.5 | 8.74 | 8.83 | 9.00 | 2.9% |
| W6×9 | 9 | 9.25 | 9.33 | 9.50 | 2.7% |
| W6×12 | 12 | 12.30 | 12.33 | 12.51 | 2.5% |
| W6×15 | 15 | 15.39 | 15.43 | 15.65 | 2.6% |
| W6×16 | 16 | 16.34 | 16.34 | 16.52 | 2.1% |
| W6×20 | 20 | 20.43 | 20.43 | 20.66 | 2.2% |
| W6×25 | 25 | 25.44 | 25.44 | 25.67 | 1.8% |
| W8×10 | 10 | 10.28 | 10.38 | 10.57 | 2.8% |
| W8×13 | 13 | 13.33 | 13.38 | 13.58 | 2.6% |
| W8×15 | 15 | 15.34 | 15.38 | 15.58 | 2.3% |
| W8×18 | 18 | 18.40 | 18.44 | 18.68 | 2.2% |
| W8×21 | 21 | 21.45 | 21.45 | 21.68 | 2.1% |
| W8×24 | 24 | 24.46 | 24.50 | 24.76 | 1.9% |
| W8×28 | 28 | 28.50 | 28.50 | 28.76 | 1.8% |
| W8×31 | 31 | 31.57 | 31.57 | 31.87 | 1.8% |
| W8×35 | 35 | 35.57 | 35.57 | 35.87 | 1.6% |
Estimates: the zinc on the coated surface, fillets ignored. ASTM A123 sets a minimum average; galvanizers often apply more, and steels with higher silicon or phosphorus react faster and coat thicker, so check the mill test report chemistry when the coating weight matters.
ASTM A123 coating grades for solar piles
ASTM A123 grades the zinc on structural steel by the measured thickness of the steel: grade 75, a minimum average of 3.0 mil, for steel from 1/8 in. to under ¼ in., and grade 100, 3.9 mil, from ¼ in. up. The light tracker piles sit below ¼ in. on both web and flanges: W6×8.5, W6×9 and W8×10 need grade 75 throughout. From W6×12 up the flanges reach ¼ in. and take grade 100, and from W6×16 the web does too.
The standard sets a floor, not a design. Solar specifications often call for a heavier coating, chosen from the soil resistivity, pH, chlorides and sulfates in the geotechnical report and the project design life. Heavier coatings depend partly on the steel chemistry, so the mill and the galvanizer need the coating specification before the steel is ordered.
surface (ft²/ft) = (2d + 4bf − 2tw) ÷ 12
zinc (lb/ft) = surface × coating mass (g/m²) ÷ 4,882
A123 minimum: web at its grade, flanges at theirs (grade 75 = 530 g/m², grade 100 = 705 g/m²)
pile weight (lb) = (bare lb/ft + zinc lb/ft) × length (ft)
Worked example: W6×9 has about 2.27 ft² of surface per foot, 0.91 on the web and 1.36 on the flanges, all at grade 75. That is 2.27 × 530 ÷ 4,882 ≈ 0.25 lb of zinc per foot, so a 14 ft pile weighs 126 + 3.45 ≈ 129.4 lb, and 2,000 of them about 258,895 lb.
How many piles does a solar project need?
The pile count follows the racking layout. Divide the DC capacity by the module power for the number of modules, divide by the modules on one tracker row and round up to whole rows, then multiply by the piles per row from the racking drawings. Fixed-tilt tables work the same way with modules and piles per table.
modules = MWdc × 1,000,000 ÷ module watts
rows = modules ÷ modules per row, rounded up
piles = rows × piles per row
With 600 W modules, 90 modules per row and 11 piles per row, a 100 MWdc project has 166,667 modules in 1,852 rows and needs 20,372 piles, about 204 per MWdc. Published counts for recent single-axis tracker projects work out to roughly 140 to 220 piles per megawatt; fixed-tilt and older designs can run higher. The pier table then splits the count into sections and lengths, and the test pile program usually comes first.
Sections outside the AISC list
Some mills roll lighter W6 sections for solar, such as W6×7, W6×7.75 and W6×10.4, and roll-formed C, U and sigma piles are sized to each racking design. Their weights come from the producer’s own dimensions, so they are not in these tables. For roll-formed piles, the purlin weight calculator figures a C section from its depth, flange, lip and thickness.
Mona Steel supplies W-Beam, C, U and sigma solar piles for utility-scale and commercial projects: cut to the pier-table lengths, punched or slotted to your racking drawings, hot-dip galvanized, bundled and labeled by block, and delivered in releases that follow the pile-driving schedule. Send the pile schedule and drawings, or hand this calculation over with “Send this to our estimators”.
Solar piles for utility-scale projects Request a pile quote
Questions
How much does a W6×9 solar pile weigh?
W6×9 weighs 9 lb/ft bare (13.4 kg/m), so a 14 ft pile is 126 lb of steel. Hot-dip galvanized to the ASTM A123 minimum it comes to about 129.4 lb, and with a 3.9 mil coating about 130.6 lb. Galvanizers often put on more zinc than the minimum, so a scale weight can run a little higher.
What size are solar piles?
Driven solar piles are mostly W6 and W8 wide flange sections. The AISC sizes run from W6×8.5 at 8.5 lb/ft to W8×35 at 35 lb/ft, and W6×9 and W6×12 are among the most common for single-axis trackers. Piles are cut to the lengths in the racking pier table, often about 10 to 20 ft. Some mills also roll lighter W6 sections outside the AISC list, such as W6×7; those are quoted on the mill’s own dimensions.
How much weight does galvanizing add to a solar pile?
For W6×9, zinc at the ASTM A123 minimum adds about 0.25 lb/ft (2.7% of the bare weight). A 3.9 mil coating adds about 0.33 lb/ft (3.6%) and a 6.0 mil coating about 0.50 lb/ft (5.5%). The zinc weight is the coated surface, about 2.27 ft² per foot of W6×9, times the coating mass.
What galvanizing thickness does ASTM A123 require on a W6×9 pile?
Grade 75, a minimum average of 3.0 mil (75 µm). ASTM A123 grades structural steel by its measured thickness, and both the web (0.170 in.) and the flanges (0.215 in.) of W6×9 are under ¼ in. On W6×12 the flanges are 0.280 in., so they need grade 100, 3.9 mil (100 µm). Many solar specifications call for a heavier coating, chosen from the soil corrosivity and the design life.
How many piles does a 100 MW solar project need?
It depends on the layout. Divide the DC capacity by the module power to get the modules, divide by the modules per tracker row to get the rows, and multiply by the piles per row. With 600 W modules, 90 modules per row and 11 piles per row, 100 MWdc takes 1,852 rows and 20,372 piles, about 204 per MWdc. Published counts for recent single-axis tracker projects work out to roughly 140 to 220 piles per megawatt; fixed-tilt and older designs can run higher.
Can I send a pile schedule for a quote?
“Send this to our estimators” opens the quote form with the section, pile length, pile count and coating already in the message box; it carries no personal data. For a full package, attach the pile schedule and the punching drawings. Mona Steel supplies W-Beam, C, U and sigma solar piles cut to length, punched or slotted to your drawings and hot-dip galvanized, with deliveries staged by block.
Request a quote
Send us the drawing, or the cut list.
We take DXF, DWG and STEP files, dimensioned PDFs and bills of material. Our estimating team reviews every request and comes back with an itemized quote.
- DXF
- DWG
- STEP
- XLS/CSV